SQUARE FOOTAGE
With over 50,000 sq. ft., the Sino Favour Centre is the network home to submarine cable operators, national and metro carriers, voice carriers, retail service carriers, data centers, VoIP providers, EFTNs, wholesale providers, FTNS and MVNOs.
These carriers take advantage of fast and direct interconnection between other networks in the HKCOLO meet-me room, without the expensive cost of local loop charges.

With over 50,000 sq. ft., the Sino Favour Centre is the network home to submarine cable operators, national and metro carriers, voice carriers, retail service carriers, data centers, VoIP providers, EFTNs, wholesale providers, FTNS and MVNOs.
These carriers take advantage of fast and direct interconnection between other networks in the HKCOLO meet-me room, without the expensive cost of local loop charges.

FLOOR SPECS
- There are raised floors throughout the building.
- The raised floor tiles are 600 x 600 mm.
- The clearance from the concrete floor to the top of the raised floor is approximately 300 mm.
- Floor loading is 750kg per square metre.
- The clearance from the top of the raised floor to the beam is 2.5.

- There are raised floors throughout the building.
- The raised floor tiles are 600 x 600 mm.
- The clearance from the concrete floor to the top of the raised floor is approximately 300 mm.
- Floor loading is 750kg per square metre.
- The clearance from the top of the raised floor to the beam is 2.5.

EQUIPMENT SPECS
- Standard 19" racks available.
- 23" racks available on special order.
- Standard cable traybasket is provided.
- Space on the Krones and panels in the existing MDF/DDF/ODF are provided to terminate cable.

- Standard 19" racks available.
- 23" racks available on special order.
- Standard cable traybasket is provided.
- Space on the Krones and panels in the existing MDF/DDF/ODF are provided to terminate cable.

CLIMATE CONTROL
- Stable temperature, 21 degrees Celsius, +/- 3 degrees, is maintained throughout the building 24 x 7.
- Humidity is maintained in the range of 40-60 percent.
- Full computer-room grade HVAC system.

- Stable temperature, 21 degrees Celsius, +/- 3 degrees, is maintained throughout the building 24 x 7.
- Humidity is maintained in the range of 40-60 percent.
- Full computer-room grade HVAC system.

POWER PROTECTION
- Independent electricity, 220/380 volt AC and 50 Hz, supplied from utility by ring-circuit, provides highest reliability and no single point of failure.
- -48 volt DC power supplyrectifier system (N+1, 10 minutes battery backup).
- 220/380 volt AC UPS with N+1, 10 minutes battery backup.
- 100% electricity loading backup by standard power generator.
- Multiple UPS and fuel reserve.

- Independent electricity, 220/380 volt AC and 50 Hz, supplied from utility by ring-circuit, provides highest reliability and no single point of failure.
- -48 volt DC power supplyrectifier system (N+1, 10 minutes battery backup).
- 220/380 volt AC UPS with N+1, 10 minutes battery backup.
- 100% electricity loading backup by standard power generator.
- Multiple UPS and fuel reserve.